Known Issues- Viewing Run Results

Local system monitor

After you run a test or component with the local system monitoring option activated when the test or component is either very short, or the number of seconds entered for the Enable local system monitoring every: __ seconds option is high (a high percentage relative to the length of your entire test run), then when you select one of the last steps in the Run Results tree, the Current Step indicator in the System Monitor pane may jump to a position outside (to the right) of the graph.

Workaround: Add a Wait statement to the end of the test or reduce the number of seconds entered in the Enable local system monitoring every: __ seconds option.

Run session errors Errors during the run session produce more than one error node in the run results.
Exporting run results
  • Exporting run results. When UAC is set to ON and you select to export the Run Results to a system folder, the exported file is stored under Virtual Storage rather than under the specified folder. (Relevant for Windows 7, Windows Server 2008 R2, Windows 8.x, and Windows Server 2012)