Siebel Tab (Record and Run Settings Dialog Box)

This tab enables you to define how UFT One starts recording and running tests on Siebel objects.

To access

Select Record > Record and Run Settings and select the Siebel tab.

Important information
  • You must open the Siebel application with Siebel Test Automation loaded, by specifying additional URL parameter values. For details, see Siebel Test Automation Module configuration.
  • If you select the Open the following application when a record or run session begins option, UFT One automatically appends the Siebel Test Automation information to the URL (you do not need to specify it manually in the URL). If you select to record and run on any open browser, you must specify the required parameter values as part of the application URL when you open the application.
  • If you select the Open the following application when a record or run session begins option, and specify the password in the Siebel automation access code section, UFT One automatically appends the password information to the URL. You do not need to specify it manually in the URL. If you select to record and run on any open browser, or do not specify the password, you must specify the required password values as part of the application URL when you open the application.
  • If a session timeout error occurs in your application, the Siebel Test Automation URL parameter values are not saved. After you log out and log in again, you must navigate to the correct URL that contains the required Siebel Test Automation parameter values.
Relevant tasks

Environment variables for Siebel applications

See also

Define record and run settings

User interface elements are described below:

UI Elements

Description

Siebel version

Specifies the Siebel version for the applications on which you want to record your test. The version that you choose remains selected for all subsequent tests.

You can use an environment variable to specify the Siebel version. For details, see Environment variables for Siebel applications.

Record and run tests on any open browser

Instructs UFT One to use any Internet Explorer browser to record and run the test.

UFT One can record and run only browsers that are opened after UFT One is opened.make sure you specify the required test automation parameters, as described in Siebel Test Automation Module configuration.

Open the following application when a record or run session begins

Instructs UFT One to open the specified application when record or run sessions begin.

Address
(Enabled only when "Open the following application when a record or run session begins" is selected)

Instructs UFT One to open Internet Explorer to the specified URL. Recommended format: <host>/<application name>/start.swe

siebapp/callcenter_enu/start.swe

You can use an environment variable to specify the URL.

Auto-login
(Enabled only when "Open the following application when a record or run session begins" is selected)

Instructs UFT One to open the specified Siebel application using the specified login details.

You can use an environment variable to specify the Auto-login setting.

User
(Enabled only when Auto-login is selected)

The user name used to log in to the specified application.

You can use an environment variable to specify the user name..

Password
(Enabled only when Auto-login is selected)

The password for the specified user name.

You can use an environment variable to specify the password.

Log out of the application when the test closes
(Enabled only when Auto-login is selected)

Instructs UFT One to log out of the specified application automatically when the test closes. Any other Siebel sessions that were opened before, during, or after the test run are not affected.

You can use an environment variable to specify the Log out setting.

Close the browser when the test closes
(Enabled only when "Open the following application when a record or run session begins" is selected)

Instructs UFT One to close the opened browser when the test closes. Any other browsers that were opened before, during, or after the test run are not affected.

Advanced
(Enabled only when "Open the following application when a record or run session begins" is selected)
  • Siebel automation request timeout. The timeout period (in seconds) for each attempt to connect to Siebel Test Automation when running the test.
  • Siebel automation access code. The predefined security code required to enable access to Siebel Test Automation, if specified by your organization's access security policy.