Stingray Pane (Options Dialog Box > GUI Testing Tab)
This pane enables you to configure how OpenText Functional Testing records and runs tests and business components on Stingray Objective Grid and Objective Toolkit objects.
To access |
|
Important information |
|
Relevant tasks |
Set Up Your Stingray project using the Precompiled Agent mode |
User interface elements are described below:
UI Elements |
Description |
---|---|
Support multithreaded Stingray applications |
Instructs OpenText Functional Testing to support multithreaded Stingray applications. If you are not sure whether you are working with a multithreaded Stingray application, first try to record and run on your Stingray application without selecting this checkbox. If you experience difficulties, you can select this checkbox and try again. Select this checkbox only if you are working with a multithreaded application. |
Cache MFC map |
Instructs OpenText Functional Testing to use auxiliary caching as a backup for MFC's internal mapping of window handles to Visual C++ objects. If OpenText Functional Testing cannot identify one or more Stingray controls while recording or running a test or business component, you can select this checkbox to instruct OpenText Functional Testing to use a cached map instead of using the Stingray application for identification. |
Use displayed (formatted) data in table checkpoints |
Instructs OpenText Functional Testing to use the formatted data value in the Stingray grid control. You can use this option when working with table checkpoints (not supported for business components). For example, if the actual value of a cell in a Stingray application is formatted to display two digits to the right of the decimal point, OpenText Functional Testing will use that rounded number instead of the actual number when checking the value during the run session. |
Record cell editing options using |
Instructs OpenText Functional Testing to record typing operations in a Stingray grid (edit) cell using one of the following options:
|
Do not use Stingray Add-in support for these applications: (Specify application process names separated by commas) |
Instructs OpenText Functional Testing to treat the applications you specify as non-Stingray applications. Some open, non-Stingray processes (such as explorer.exe) can cause unexpected behavior when recording and running tests and business components on Stingray applications. By adding the process names to this edit box, you can help prevent this unexpected behavior.
|
Stingray version |
Indicates the versions of the Stingray Objective Grid and Stingray Objective Toolkit libraries used for identifying Stingray objects in your application (read-only). |
Select Version |
Opens the Stingray Support Configuration Wizard, which enables you to select the combination of Objective Grid and Objective Toolkit versions with which you want to work. For details, see Stingray Support Configuration Wizard. |
Generate diagnostic agent log |
Instructs OpenText Functional Testing to generate a diagnostic agent log file. You can use this option if you encounter problems with the Stingray Add-in, for example, if OpenText Functional Testing does not recognize a Stingray grid control while recording. OpenText Software Support may ask you to generate this log and send it together with your service request. When you select this checkbox, the following options are enabled: If you select this checkbox, you must specify the location for the generated log. For details, see Specify location(s) for the generated log. |
Include detailed log information for this control |
Instructs OpenText Functional Testing to include detailed information in the generated log for a specific Stingray control, in addition to the general OpenText Functional Testing/agent communication log information. For example, you may want to generate additional log details for a specific Stingray grid. To select the object for which you want to generate detailed log information: Click the pointing hand and then click the relevant Stingray control. The selected object's window handle is displayed in the edit box. This option is available only when the Generate diagnostic agent log checkbox is selected. |
Specify location(s) for the generated log |
Instructs OpenText Functional Testing to generate the log to the selected locations. You can select one or both of the following options:
These options are available only when the Generate diagnostic agent log checkbox is selected. |